Time-delay CUBE Fuse up to 400 amps.Finger-safe, Class J electrical performance requires up to 70% less space
Catalog symbols: • TCF-_
Description: In addition to having the smallest footprint of any Class CC, J or RK fuse solution, the Bussmann series LowPeak CUBE Fuse is the only product included in the UL Class CF. It’s a current-limiting, dual-element, time-delay branch circuit fuse with Class J electrical performance. And it features industry-first plug-in capability for easier installation.
Specifications:
Ratings
• Volts:
• 600 Vac
• 300 Vdc
• Amps: • 6 to 400 A (indicating) • 1 to 400 A (non-indicating)
• IR
• 300 kA RMS Sym. (up to 100 A UL)
• 200 kA RMS Sym. (110 to 400 A UL)
• 200 kA RMS Sym. (Up to 100 A CSA®)
• 100 kA DC (up to 400 A UL and up to 100 A CSA)
Agency information:
• UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A)
• CSA Certified fuse: Class 1422-02, File 053787_C_000 (up to 100 A)
• CE (100 A and below)
• RoHS Compliant
Catalog Numbers (Amps)
Catalog Numbers
Catalog Numbers
Catalog Numbers
Catalog Numbers
TCF6
TCF35
TCF90
TCF225
TCF10
TCF40
TCF100
TCF250
TCF15
TCF45
TCF110
TCF300
TCF17-1/2
TCF50
TCF125
TCF350
TCF20
TCF60
TCF150
TCF400
TCF25
TCF70
TCF175
TCF30
TCF80
TCF200
Carton Quantity
Amp Rating
Carton Qty.
6-60
12
70-100
6
110-400
1
Features
• Finger-safe construction for enhanced safety*
• Amp rating rejection helps prevent overfusing by rejecting higher fuse amp ratings
• Smallest installed fuse and holder footprint of any Class J or R installation
• All holders dovetail together to create the required number of poles, mixed 30, 60 and 100 A holders dovetail together
• 30, 60 and 100 A holders have dual wire rated box lug terminals for wiring ease
• 200, 225 and 400 A holders available with a variety of lugs and terminal shrouds for application flexibility
• Up to 300 kA SCCR withstands high fault currents
* 200, 225 and 400 A holders require installed shrouds
Typical applications
• Electrical panelboards
• Machinery disconnects
• Industrial controls and panels
• Required finger-safe systems
Catalog no
Max holder amps
Fuse amp range
600 V UL Listed
TCFH30N
30
1-30
TCFH60N
60
1-60
TCFH100N
100
1-100
TCFH200N
200
110-200
TCFH225N
225
110-225
TCFH400N
400
110-400
690 V UL Recognized
TCFH30NW
30
1-30
TCFH60NW
60
1-60
TCFH100NW
100
1-100
Catalog number
Amps
Description
CCP2-(pole)-30CF
30
Switch only
CCP2-(pole)-60CF
60
CCP2-(pole)-100CF
100
CCP2-(pole)-200CF
200
Switch only*
CCP2R-(pole)-30CF
30
Right front rotary, clockwise operated switch
CCP2R-(pole)-60CF
60
CCP2R-(pole)-100CF
100
CCP2RL-(pole)-30CF
30
Left front rotary, clockwise operated switch
CCP2RL-(pole)-60CF
60
CCP2RL-(pole)-100CF
100
CCP2S-(pole)-30CF
30
Right side rotary, clockwise operated switch
CCP2S-(pole)-60CF
60
CCP2S-(pole)-100CF
100
CCP2SL-(pole)-30CF
30
Left side rotary, counterclockwise operated switch
CCP2SL-(pole)-60CF
60
CCP2SL-(pole)-100CF
100
*Rotary operators for 200 A CCP are available as accessories, for front or side (left or right) operation. Front rotary operators are available with 3-pole switches only, while the side operator may be applied to 1-, 2- or 3-pole units.
*Finger-safe depends on final, installed application, and will require using accessory shrouds for 110 to 400 A ratings.
-