Low-Peak™ LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses
-
Low-Peak™ LPJ Class J 600Vac/300Vdc, 70-600A, dual element, time-delay fuses
Low-Peak™ LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses
Catalog symbol :
-
LPJ-(amp)SP (non-indicating)
-
LPJ-(amp)SPI (indicating)
Description::
Bussmann® series Ultimate protection LPJ Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication. Timedelay – 10 seconds (minimum) at 500% of rated current.
Specifications: Ratings
Volts
-
600Vac
-
300Vdc*
Amps : 1-60A
IR :
-
300kA Vac RMS Sym.
-
100kA Vdc
* Indicating versions not Vdc rated.
Agency information
-
UL® Listed, Guide JDDZ, File E4273
-
CSA® Certified, Class 1422-02, File 53787, Class J per CSA 22.2 No. 248.
-
CE
-
RoHS compliant
Catalog numbers (amps) – non-indicating fuses
Catalog Numbers
Catalog Numbers
Catalog Numbers
Catalog Numbers
LPJ-1SP
LPJ-3SP
LPJ-7SP**
LPJ-25SP**
LPJ-1-1⁄4SP
LPJ-3-2⁄10SP
LPJ-8SP**
LPJ-30SP**
LPJ-1-6⁄10SP
LPJ-3-1⁄2SP
LPJ-9SP**
LPJ-35SP**
LPJ-1-8⁄10SP
LPJ-4SP
LPJ-10SP**
LPJ-40SP**
LPJ-2SP
LPJ-4-1⁄2SP
LPJ-12SP**
LPJ-45SP**
LPJ-2-1⁄4SP
LPJ-5SP
LPJ-15SP**
LPJ-50SP**
LPJ-2-1⁄2SP
LPJ-5-6⁄10SP
LPJ-17-1⁄2SP**
LPJ-60SP**
LPJ-2-8⁄10SP
LPJ-6SP**
LPJ-20SP**
* Open fuse indication available by inserting the suffix “I,” e.g., LPJ-15SPI. Requires 75Vac minimum voltage. Indicating fuses are not Vdc rated.
Carton Quantity
Amp rating
Carton qty
1-60
10
Features:
-
Industry’s only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application.
-
Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection.
-
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses.
-
Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective coordination easy.
-
Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.
-
Current-limitation protects downstream components against damaging thermal and magnetic effects of short-circuit currents.
-
Dual-element fuses have lower resistance than ordinary fuses so they run cooler. They can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.
-
Proper sizing can provide “no damage” Type 2 coordinated protection for NEMA® and IEC® motor controllers.
-
Space-saving package for equipment downsizing.
Recommended fuse blocks and holders:
Fuse amps
1-Pole
2-Pole
3-Pole
Modular open blocks with optional covers
0-30
JM60030-1_
JM60030-2_
JM60030-3_
35-60
JM60060-1_
JM60060-2_
JM60060-3_
“Pyramid” blocks
0-30
—
—
JP60030-3_
CH holders
0-30
CH30J1_
CH30J2_
CH30J3_
35-60
CH60J1_
CH60J2_
CH60J3_
Safety J™ holders
0-30
JT60030_
—
—
35-60
JT60060_
—
—
For additional information on the Class J fuse blocks and holders, see data sheets no. 10289 (modular open blocks), no.1108 (pyramid blocks), no. 2144 (CH) and no. 1152 (Safety J).
Fuse reducers for Class J fuses:
Equipment fuse clips
Desired fuse (case size)
Catalog no. (pairs)
60A
30A
J-63
100A
30A
J-13
60A
J-16
200A
60A
J-26+
† Not for bolt-in applications.
Current-limiting effects:
Prospective S.C.C.
Let-through current
(apparent RMS symmetrical vs. fuse rating)
15A
30A
60A
1000
1000
1000
1000
3000
1000
1000
1000
5000
1000
1000
1000
10000
1000
1000
2000
15000
1000
1000
2000
20000
1000
1000
2000
25000
1000
1000
2000
30000
1000
1000
2000
35000
1000
1000
2000
40000
1000
2000
3000
50000
1000
2000
3000
60000
1000
2000
3000
80000
1000
2000
3000
100000
1000
2000
4000
150000
1000
2000
4000
200000
2000
3000
4000
250000
2000
3000
5000
300000
2000
3000
5000
Low-Peak™ LPJ Class J 600Vac/300Vdc, 70-600A, dual element, time-delay fuses
Catalog symbols:
-
LPJ-(amp)SP (non-indicating)
-
LPJ-(amp)SPI (indicating)
Description:
Bussmann® series Ultimate protection LPJ Class J dual element, current-limiting, time-delay fuses available with optional open fuse indication. Timedelay – 10 seconds (minimum) at 500% of rated current.
Specifications:
Ratings
Volts :
-
600Vac
-
300Vdc*
Amps : 70-600A
IR
-
300kA Vac RMS Sym.
-
100kA Vdc
* Indicating versions not Vdc rated
Agency information :
-
UL® Listed, Guide JDDZ, File E4273
-
CSA® Certified, Class 1422-02, File 53787, Class J per CSA C22.2 No. 248.8
-
CE
-
RoHS compliant
Catalog numbers (amps) – non-indicating fuses
Catalog Numbers
Catalog Numbers
Catalog Numbers
Catalog Numbers
LPJ-70SP**
LPJ-125SP**
LPJ-250SP**
LPJ-500SP**
LPJ-80SP**
LPJ-150SP**
LPJ-300SP**
LPJ-600SP**
LPJ-90SP**
LPJ-175SP**
LPJ-350SP**
LPJ-100SP**
LPJ-200SP**
LPJ-400SP**
LPJ-110SP**
LPJ-225SP**
LPJ-450SP**
*Open fuse indication available on all part numbers by inserting the suffix “I,” e.g., LPJ-90SPI. Requires 75Vac minimum voltage. Indicating fuses are not Vdc rated.
Carton Quantity :
Amp Rating
Carton Qty.
7-200A
5
225-600A
1
Features:
-
Industry’s only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application.
-
Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection.
-
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses.
-
Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective coordination easy.
-
Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges.
-
Current-limitation protects downstream components against damaging thermal and magnetic effects of short-circuit currents.
-
Dual-element fuses have lower resistance than ordinary fuses so they run cooler.
-
Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail.
-
Proper sizing can provide “no damage” Type 2 coordinated protection for NEMA® and IEC® motor controllers.
-
Space-saving package for equipment downsizing.
Recommended fuse blocks: :
Fuse amps
1-Pole
2-Pole
3-Pole
70-100
JM60100-1CR
JM60100-2CR
JM60100-3CR
110-200
JM60200-1CR
JM60200-2CR
JM60200-3CR
225-400
JM60400-1CR
JM60400-2CR
JM60400-3CR
450-600
JM60600-1CR
JM60600-2CR
JM60600-3CR
For additional information on the JM fuse blocks, see product brochure no. 3192
Fuse reducers for Class J fuses:
Equipment fuse clips
Desired fuse (case size)
Catalog no. (pairs)
100A
30A
J-13
60A
J-16
200A
60A
J-26+
100A
J-21+
400A
100A
J-41+
200A
J-42+
600A
200A
J-62+
400A
J-64+
Current-limiting effects:
Prospective S.C.C.
Let-through current
(apparent RMS symmetrical vs. fuse rating)
100A
200A
400A
600A
1000
1000
1000
1000
1000
3000
2000
2000
3000
3000
5000
2000
3000
5000
5000
10000
2000
4000
6000
8000
15000
3000
4000
7000
9000
20000
3000
4000
7000
10000
25000
3000
5000
8000
10000
30000
3000
5000
8000
11000
35000
4000
5000
9000
12000
40000
4000
6000
9000
12000
50000
4000
6000
10000
13000
60000
4000
6000
11000
14000
80000
5000
7000
12000
15000
100000
5000
8000
12000
17000
150000
6000
9000
14000
19000
200000
6000
9000
16000
21000
250000
7000
10000
17000
23000
300000
7000
11000
18000
24000
-
-